Residence on site test by main contractor Rexallent Contruction Sdh Bhd (associate of TitiJaya Sdn Bhd). One of our client on SL-J100 Fire Proof Safety Net since 2016.
![](https://static.wixstatic.com/media/678ecf_4c224b59a09b41c9868cd2e06145ffff~mv2.png/v1/fill/w_753,h_1063,al_c,q_90,enc_auto/678ecf_4c224b59a09b41c9868cd2e06145ffff~mv2.png)
Rexallent Contruction Sdh Bhd (associate of TitiJaya Sdn Bhd)
American Standard ASTM D635: 2010 - Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.
SIRIM QAS International Sdn. Bhd. Safety Link Marketing - Netstarget Malaysia. SL-J100; Safety Link (EZY) Fire-Proof Safety Net. Country of Origin: Japan. Size: 1.83m x 5.1m c/w eyelets at 4 edges. 100% High Tenacity Fire Proof PVC Coated Polyester Nets. Fireproof Requirements (B1 Grade - Fire Off in 2-3 seconds) of Japan Association of Anti-Inflammation COI-11018. Colour: Safety Blue. American Standard ASTM D635: 2010 - Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.
![](https://static.wixstatic.com/media/678ecf_a421950d696c4b258185f7bfdcceff2e~mv2.png/v1/fill/w_980,h_667,al_c,q_90,usm_0.66_1.00_0.01,enc_auto/678ecf_a421950d696c4b258185f7bfdcceff2e~mv2.png)
SIRIM QAS International SL-J100 Fire Proof Safety Net test report. Material composition is 100% high tenacity fire proof PVC coated polyester nets. Safety compliance is fireproof requirement (B1 Grade - Fire Off in 2-3 seconds) of Japan Association of Anti Inflammation COI-11018. Safety nets in safety blue colour. This product having reference standard in American Standard ASTM D635: 2010 - Standard test method for rate of burning and/or extend and time of burning of plastics in a horizontal position.
![](https://static.wixstatic.com/media/678ecf_a1221e0b52f74047a8973e589ab3fd50~mv2.jpg/v1/fill/w_262,h_403,al_c,q_80,enc_auto/678ecf_a1221e0b52f74047a8973e589ab3fd50~mv2.jpg)
SIRIM QAS International SL-J100 Fire Proof Safety Net test report. The test report conclusion is since the flame front did not reach or pass the 25mm reference mark, the sample may be classified as HB (horizontal burning). There are no visible signs of combustion after ignition source is removed. The flame front does not pass the 25 mm reference mark. The flame front passes the 25 mm reference mark but does not reach the 100 mm reference mark. The flame front reaches the 100 mm reference mark and the liner burning rate does not exceed 40mm.